Testing

Fine & Gross Leak Testing

Fine and gross leak testing of your hermetically sealed packages are completed as per MIL-STD-883 and MIL-STD-750.

We can utilize a high boiling temperature (> 250℃) oil for gross leaks or a Helium Mass Spectrometer detection system for fine leak testing.

(top)

Wire Pull & Die Shear

  • Shear test – 50 gram F to 10 kilogram F
  • Pull test – up to 50 gram F

(top)

Electrical Testing

first level inc. can supply the technical staff to do electrical testing of your product during the manufacturing process or as part of a final inpsection.

light engine being tested by applying DC current

(top)