Testing

Fine & Gross Leak Testing

Fine and gross leak testing are completed as per Military Standard specifications MIL-STD-883 and MIL-STD-750.

High boiling temperature (> 250℃) oil is used to find gross leaks in hermetically sealed electronic assemblies. A commercially manufactured Helium Mass Spectrometer detection system is used to perform fine leak testing.

(top)

Wire Pull & Die Shear

  • Shear test – 50 gram F to 10 kilogram F
  • Pull test – up to 50 gram F

(top)

Electrical Testing

(top)